The Tesla Wall Charger is the most convenient at-home and on-site charging solution for Tesla vehicles. Itโs a faster, Wi-Fi-enabled Level 2 charger that receives over-the-air updates so it keeps improving. With a suitable circuit, it delivers up to 44 miles of range per hour (11.5ย kW).
| Category | Detail |
| Type | Level 2 (240ย V), hardwired |
| Max Power | Up to 11.5ย kW (48A @ 240ย V), breaker size dependent |
| Connectivity | 2.4ย GHz Wi-Fi (OTA firmware, load sharing) |
| Cable Length | ~24ย ft |
| Connector | NACS (Tesla); adapters may enable others |
| Install | Qualified electrician recommended; 60A circuit typical for 48A output |
| Symptom | Typical Root Cause | Service Action |
| No charge / red fault ring | Relay weld, GFCI trip, PSU failure | Component-level repair, calibration, re-test |
| App wonโt connect | Wi-Fi module / config error | Module replacement, firmware, pairing |
| Cable damage / hot handle | Conductor fatigue, bent pins | Cable/handle assembly swap; pin service |
| Water ingress / corrosion | Seal breach, enclosure damage | Refurbish, re-seal, conformal coat |
| Option | Voltage / Amps | Max Power | Typical Range Added* | Use Case | We Service? |
| Level 1 Charge Cable (Mobile) | 120ย V / 12โ15A | ~1.4โ1.8ย kW | ~3โ5 mi/hr | Overnight trickle; emergencies | Yes โ cable/brick diagnostics |
| Mobile Connector on 240ย V (NEMA 14-50 or similar) | 240ย V / up to 32A** | Up to ~7.7ย kW | ~20โ30 mi/hr | Cost-effective Level 2 without hardwiring | Yes โ plug set, thermal checks |
| Tesla Wall Connector (Gen 3) | 240ย V / up to 48A | Up to 11.5ย kW | Up to 44 mi/hr | Fastest home charging; smart features; clean install | Yes โ full depot/field repair |
| J1772 Wall Connector*** | 240ย V / up to 48A | Up to 11.5ย kW | ~40+ mi/hr | Non-Tesla EVs at homes/garages (adapter for Tesla) | Yes โ diagnostics & parts |
*Range per hour varies by model, temperature, and state of charge. **Mobile Connector amperage depends on plug adapter/circuit. ***Where offered; check connector compatibility.
For best performance, use a dedicated circuit sized to your target amperage (e.g., 60A breaker for 48A charging). We recommend hiring a licensed electrician for site survey, permits, code-compliant install, and commissioning.