Battery – Auxiliary – 12V (RWD) (Remove and Replace)
FRT No: 17011002
Removal
- Disconnect the negative battery connection. Lay the negative cable to the side of the battery.
- Unplug the first responder’s loop (Do Not Cut!). Wait at least two minutes for all electrical circuits to fully discharge. Failure to unplug the first responder’s loop will void your 12V battery warranty!
Installation
- Ensure the first responder’s loop is connected before the 12V battery negative connection! This ensures the high voltage system provides 12V power to the 12V battery as soon as the 12V battery is installed. Not doing so will cause the 12V battery to discharge below a point where the high voltage system will provide 12V power and void your 12V battery warranty.